RE: What the Hell!!!!!!!!!!!
Permalink  
 


al9226 wrote:

Happened to us today.  Had two of my guys on a job today.  Called and said the pump wouldn't start.  Told them to check the fuse.... Blown fuse.... new fuse.... same prob.  Switched out pump, finished the job.   Planing a post mortum on the pump tonight or tomorrow.  Anxious to see what went wrong. 

By the way.  5850 with 1inch feed and 5/8 inch chem hose running through an accumulator with 30 tips.


 Update... took the pump off line... hooked up straight to battery.... I can hear the pump turn a couple times then lock up... little smoke from wires.. unhook....going to get a replacement head and see if I can salvage it.



__________________

Al Gigliotti

ANR Cleaning Services LLC

Orange Park Fl 32073 - 904-710-1249

http://anrcleanteam.com

http://pressurecleanjax.com

http://www.facebook.com/pages/ANR-Cleaning-Services-LLC/243026462412899



Premium Member Roof Cleaning Institute of America Certified Roof Cleaning Specialist

Status: Offline
Posts: 2066
Date:
Permalink  
 

al9226 wrote:
al9226 wrote:

Happened to us today.  Had two of my guys on a job today.  Called and said the pump wouldn't start.  Told them to check the fuse.... Blown fuse.... new fuse.... same prob.  Switched out pump, finished the job.   Planing a post mortum on the pump tonight or tomorrow.  Anxious to see what went wrong. 

By the way.  5850 with 1inch feed and 5/8 inch chem hose running through an accumulator with 30 tips.


 Update... took the pump off line... hooked up straight to battery.... I can hear the pump turn a couple times then lock up... little smoke from wires.. unhook....going to get a replacement head and see if I can salvage it.


I would'nt waste my money. It's not the head, it's the armature corroded and rusted inside = done for!

Been there, done that a dozen times-to say the least!



__________________

Serving Englewood Rotonda North Port Cape Haze Venice Port Charlotte Punta Gorda Boca Grande Charlotte and Southern Sarasota Counties in Florida.

941-698-1959
www.bergmanroofcleaning.com

 http://www.youtube.com/watch?v=4RNlN3R7CqI



Premium Member Roof Cleaning Institute of America

Status: Offline
Posts: 227
Date:
Permalink  
 

Bergman Roof Cleaning Port Charlotte FL 941-698-1959 wrote:
al9226 wrote:
al9226 wrote:

Happened to us today.  Had two of my guys on a job today.  Called and said the pump wouldn't start.  Told them to check the fuse.... Blown fuse.... new fuse.... same prob.  Switched out pump, finished the job.   Planing a post mortum on the pump tonight or tomorrow.  Anxious to see what went wrong. 

By the way.  5850 with 1inch feed and 5/8 inch chem hose running through an accumulator with 30 tips.


 Update... took the pump off line... hooked up straight to battery.... I can hear the pump turn a couple times then lock up... little smoke from wires.. unhook....going to get a replacement head and see if I can salvage it.


I would'nt waste my money. It's not the head, it's the armature corroded and rusted inside = done for!

Been there, done that a dozen times-to say the least!


Any way to keep that from happening?



__________________

Al Gigliotti

ANR Cleaning Services LLC

Orange Park Fl 32073 - 904-710-1249

http://anrcleanteam.com

http://pressurecleanjax.com

http://www.facebook.com/pages/ANR-Cleaning-Services-LLC/243026462412899



Premium Member Roof Cleaning Institute of America Certified Roof Cleaning Specialist

Status: Offline
Posts: 2066
Date:
Permalink  
 

al9226 wrote:
Bergman Roof Cleaning Port Charlotte FL 941-698-1959 wrote:
al9226 wrote:
al9226 wrote:

Happened to us today.  Had two of my guys on a job today.  Called and said the pump wouldn't start.  Told them to check the fuse.... Blown fuse.... new fuse.... same prob.  Switched out pump, finished the job.   Planing a post mortum on the pump tonight or tomorrow.  Anxious to see what went wrong. 

By the way.  5850 with 1inch feed and 5/8 inch chem hose running through an accumulator with 30 tips.


 Update... took the pump off line... hooked up straight to battery.... I can hear the pump turn a couple times then lock up... little smoke from wires.. unhook....going to get a replacement head and see if I can salvage it.


I would'nt waste my money. It's not the head, it's the armature corroded and rusted inside = done for!

Been there, done that a dozen times-to say the least!


Any way to keep that from happening?


No, not forever. However, if you always use the pump with the black plastic electronics facing down, you minimize what can run into the expensive motor. If you ruin anything, it will be the replacable head or just the demand switch.

I get twice and more the life out of my pumps by running them head down and by running 5+ gallons of water through after each use. Also, if you have a backup, or one stored, run car antifreeze through it and leave some right in there. It prevents corrosion etc.



__________________

Serving Englewood Rotonda North Port Cape Haze Venice Port Charlotte Punta Gorda Boca Grande Charlotte and Southern Sarasota Counties in Florida.

941-698-1959
www.bergmanroofcleaning.com

 http://www.youtube.com/watch?v=4RNlN3R7CqI



Guest

Status: Offline
Posts: 191
Date:
Permalink  
 

Thanks Chuck.

Good tip.



__________________

Skyline Roof Cleaning, LLC

Nokesville, VA

Al McGlinn

703-795-4636

Click Here For More Information



Premium Member Roof Cleaning Institute of America Certified Roof Cleaning Specialist

Status: Offline
Posts: 2066
Date:
Permalink  
 

Skyline Roof Cleaning Virginia wrote:

Thanks Chuck.

Good tip.


 Sure! I am not laying claim to the idea. I learned it right here at RCIA!



__________________

Serving Englewood Rotonda North Port Cape Haze Venice Port Charlotte Punta Gorda Boca Grande Charlotte and Southern Sarasota Counties in Florida.

941-698-1959
www.bergmanroofcleaning.com

 http://www.youtube.com/watch?v=4RNlN3R7CqI



Premium Member Roof Cleaning Institute of America

Status: Offline
Posts: 227
Date:
Permalink  
 

Bergman Roof Cleaning Port Charlotte FL 941-698-1959 wrote:
al9226 wrote:
Bergman Roof Cleaning Port Charlotte FL 941-698-1959 wrote:
al9226 wrote:
al9226 wrote:

Happened to us today.  Had two of my guys on a job today.  Called and said the pump wouldn't start.  Told them to check the fuse.... Blown fuse.... new fuse.... same prob.  Switched out pump, finished the job.   Planing a post mortum on the pump tonight or tomorrow.  Anxious to see what went wrong. 

By the way.  5850 with 1inch feed and 5/8 inch chem hose running through an accumulator with 30 tips.


 Update... took the pump off line... hooked up straight to battery.... I can hear the pump turn a couple times then lock up... little smoke from wires.. unhook....going to get a replacement head and see if I can salvage it.


I would'nt waste my money. It's not the head, it's the armature corroded and rusted inside = done for!

Been there, done that a dozen times-to say the least!


Any way to keep that from happening?


No, not forever. However, if you always use the pump with the black plastic electronics facing down, you minimize what can run into the expensive motor. If you ruin anything, it will be the replacable head or just the demand switch.

I get twice and more the life out of my pumps by running them head down and by running 5+ gallons of water through after each use. Also, if you have a backup, or one stored, run car antifreeze through it and leave some right in there. It prevents corrosion etc.


 Looks like I'm going to change my layout and hang it motor up.  I have it lying flat right now 2" off the floor.  I did see some corrosion on the bottom of the motor when I took it out.



__________________

Al Gigliotti

ANR Cleaning Services LLC

Orange Park Fl 32073 - 904-710-1249

http://anrcleanteam.com

http://pressurecleanjax.com

http://www.facebook.com/pages/ANR-Cleaning-Services-LLC/243026462412899



Guest

Status: Offline
Posts: 1
Date:
Permalink  
 

Exactly Lori.  1/2" hose, 1/2" poly guns, and nozzles smaller than #40 will cause premature failure.

For the 5850 pump use 5/8" output hose, 3/4"-1" intake hose, 3/4" ball valve, and #40 nozzle.  Use 10-14 gauge wire.
My 5850's last up to 2 years with no problems.
The black poly head will crack and leak after about 2 years.
Replacing just the upper housing (head) only costs around $30 I believe.  It's been a while since I ordered one.
 
 
 
 
 
Where can one purchase the upper house (head) for the Delevan?
 
 

 

 





__________________
«First  <  1 2 3 | Page of 3  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us


Create your own FREE Forum
Report Abuse
Powered by ActiveBoard