The Roof Cleaning Institute Of America Training & Certification Forum
"Find A Certified Roof Cleaner Directory"

Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: photos of piping for fill and spray


Guest

Status: Offline
Posts: 23
Date:
photos of piping for fill and spray
Permalink  
 


I saw a post recently asking about diagrams for piping that would direct the flow into or out of the tank with the same pump. Here is my setup.

Attachments
__________________
NONE


guest

Status: Offline
Posts: 2289
Date:
Permalink  
 

Gilbo wrote:

I saw a post recently asking about diagrams for piping that would direct the flow into or out of the tank with the same pump. Here is my setup.



Gil
That set up looks pretty sophisticated. Can you give some more details on what you have done and why?

 



__________________
H20 POWERWASHING
Roof Cleaning Lanoka Harbor NJ 08734
clydesampsel@gmail.com
www.roofcleaningjerseyshore.com



Premium Member Roof Cleaning Institute Of America Certified Roof Cleaning Specialist-MODERATOR

Status: Offline
Posts: 2142
Date:
Permalink  
 

Very nice set up. I've got mine set up somewhat similar. Just do yourself a huge favor and get an in line filter between your compressor and your air flow pump. You wouldn't believe the moisture that it traps. Not having one on there will cause your Roof Cleaning pump to stop pumping and could damage it. They are only $12.00 @ Home Depot or Lowe's. They will save you a TON of grief. Trust me.

This manifold/valve system is just for my 12volt pump.



Attachments
__________________

All Surface Roof Cleaning
Largo FL

(727) 543-3276
Roof Cleaning Video
Tile Roof Cleaning�Palm Harbor�Florida
Larry Millette
 Roof Cleaning & Pressure Washing Florida.

  Roof Cleaners Clearwater, Pressure Washers Florida  Roof Cleaners Saint, Petersburg FL 



Guest

Status: Offline
Posts: 97
Date:
Permalink  
 

Thanks you guys. I have been looking for stuff like this, my pump etc should be here soon...

__________________

Jeromy Ashcraft

Satcahr - Handyman Services

www.satcahr.com

Done once, Done right!



Guest

Status: Offline
Posts: 237
Date:
Permalink  
 

Gilbo wrote:

I saw a post recently asking about diagrams for piping that would direct the flow into or out of the tank with the same pump. Here is my setup.





Feeding from the bottom?

__________________

 

Ada Mobile Wash

2694 Ashville Dr. NE

Grand Rapids, MI 49525


616-285-8115

kennethpaul@vzw.blackberry.net


Roof Washing Exterior House Cleaning Grand Rapids, MI



RCIA Founder

Status: Offline
Posts: 7908
Date:
Permalink  
 

KP Diamond wrote:

Gilbo wrote:

I saw a post recently asking about diagrams for piping that would direct the flow into or out of the tank with the same pump. Here is my setup.




 


Feeding from the bottom?




I SAW that Too !!!
Hey man, we all live in the real world.
Several already have tanks with bulkheads cut in the bottom!
We use what we got.

They will soon learn, as we did, that the SH will find it's way OUT of the bulkhead.
But, by then, they will have  made enough money to do it right roof cleaning

 
That is, if a rusted out driveshaft don't find it's way up their azz first ?

Trust me, you have not "lived" until a driveshaft/u-joints snap at 70 mph from SH dripping on it.
Or, until you hit a pot hole, your rusted springs break, and you find yourself upside down with 600 gallons of SH in your tank leaking all over the roadside ?

But the piping systems displayed are all VERY Impressive otherwise.
Good Job Guys!

KEEP your eyes on that bulkhead fitting ?

Heyward, or Hayward makes a very good bulkhead fitting with Viton/Teflon O Rings.

EDPM O Rings is NOT good enough for constant SH exposure!

Also, tanks flex, especially big ones.

It is a good practice to chech tightness every 3 months or so of the bulkhead fitting ?






__________________


Apple Roof Cleaning Tampa Florida

711 Westbrook

Brandon, FL 33511

813 655 8777

See our website here 

Click here for more information

Here are more of our services

Watch a short video

 




 



Guest

Status: Offline
Posts: 454
Date:
Permalink  
 

confuseGilbo, put some hose in those lines for movement and vibration before you have a situation like Chris has mentioned

__________________
Roof Cleaning Long Island New York (631) 220 6985


Guest

Status: Offline
Posts: 123
Date:
Permalink  
 

Have any of you guys tried plastic welding?  Thought about picking one up or having a friend of mine weld an older tank that has an outlet on the bottom.

__________________

PowerhouseCleaner.com
info@PowerhouseCleanersCo.com



RCIA Founder

Status: Offline
Posts: 7908
Date:
Permalink  
 

PowerClean wrote:

Have any of you guys tried plastic welding?  Thought about picking one up or having a friend of mine weld an older tank that has an outlet on the bottom.




We buy our tanks right from a tank plant!
We no longer use 500 to 600 gallon tanks, too many leak problems.
On leaking tanks, they fix them at the plant with a router, and a nylon  disc.
They put the nylon disc in a router, and start routing the tank, and the nylon melts into the tank.
Works great, until the SH attacks the nylon, and the guy in the car next to you says "Your tank is spilling water on my car"
Then it is time to say Thanks, and get the heck OUTTA there, quick roof cleaning


 



__________________


Apple Roof Cleaning Tampa Florida

711 Westbrook

Brandon, FL 33511

813 655 8777

See our website here 

Click here for more information

Here are more of our services

Watch a short video

 




 



Guest

Status: Offline
Posts: 123
Date:
Permalink  
 

LOL...  That's not a Kodak moment I want to EVER experience. 

Wasn't sure how that would hold up in the long run.  So, if there's a will, the LOVE will find a way. 

Guess I have another use for that old tank.

__________________

PowerhouseCleaner.com
info@PowerhouseCleanersCo.com



Guest

Status: Offline
Posts: 110
Date:
Permalink  
 

So are ya'll saying that only certain'pump systems' will work with the LOVE or certain tanks?And which one of each do ya'll recommend.I was looking to but one of those tanks like many farmers use to spray their fields with whatever they use.Thanks

__________________


National Cleaning Expo's

Status: Offline
Posts: 2147
Date:
Permalink  
 

Gilbo wrote:

I saw a post recently asking about diagrams for piping that would direct the flow into or out of the tank with the same pump. Here is my setup.




 That a serious hook up



__________________

Ron Musgraves

National Cleaning Expos
480-522-5227
Mobile Cleaning Contractor Education Seminars Roundtables

Like Us On Facebook 
Pressure Washing Institute Roof Cleaning Forum



Guest

Status: Offline
Posts: 91
Date:
Permalink  
 

Larry,

You & Gilbo both have a real nice set plumbing up for your rigs. Ours is fairly similar. We have All Flo pumps and have it set up to pump from our storage tank to the tanks on our rig. Your right about that moisture filter definately a must. Sorry no pics, our rig is still in storage. Snowing.

Mike  



__________________
Danny and Mike Spiczenski




Indiana Roof Cleaning
Safe Roof Cleaning
Non Pressure Roof Cleaning Indianapolis
Black Streak Removal


www.StopTheStreaking.com







Guest

Status: Offline
Posts: 53
Date:
Permalink  
 

do yall use your same pump that you spray the cleaning solution w/ to also pump the SH into the holding tank when making your mixture? can the pump handle straight SH?

__________________

Zeke Bullock
Dallas- Ft Worth Tx Shingle Shine
Roof Cleaning Dallas Texas



Guest

Status: Offline
Posts: 188
Date:
Permalink  
 

i do,i just have a cut off valve and a T valve that i use to pump straight from my tank ! and then i take that same hose and run about 30 gallons of water thur it! just dont  forget to rinse VERY WELL! 

__________________

Bayou Power Washing & Roof Cleaning
 318-614-0108



guest

Status: Offline
Posts: 2083
Date:
Permalink  
 

I am thinking of using aluminum banding to hold my tanks in on my new trailer. Should have the trailer soon. I always like the board layouts for valving, looks very clean. I can't decide if I want to use all thread and hanger supports on gray chem pvc or if I want to lay all pipes down on the trailer bed. Either way I will have a riser on my top feed tanks and I feel it needs a hanger of some kind.

__________________

Bill Booz

Accuwash LLC

Cell-240-425-2845

 



Guest

Status: Offline
Posts: 123
Date:
Permalink  
 

Baltimore MD Roof Cleaning 410-482-4367 wrote:

I am thinking of using aluminum banding to hold my tanks in on my new trailer. Should have the trailer soon. I always like the board layouts for valving, looks very clean. I can't decide if I want to use all thread and hanger supports on gray chem pvc or if I want to lay all pipes down on the trailer bed. Either way I will have a riser on my top feed tanks and I feel it needs a hanger of some kind.



I would think laying the pipes down would be a cleaner look but would it take up more space Bill?  Not sure, you're better at this game than I am.  I'm working on a new trailer setup as well.

Maybe I should talk to Dave W. from Roof Clean USA first?  I hear he knows a thing or two about trailer setups?? LOL...

 



__________________

PowerhouseCleaner.com
info@PowerhouseCleanersCo.com

Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us