The Roof Cleaning Institute Of America Training & Certification Forum
"Find A Certified Roof Cleaner Directory"

Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: Variable Chemical Strength Roof Cleaning System


RCIA Founder

Status: Offline
Posts: 7908
Date:
Variable Chemical Strength Roof Cleaning System
Permalink  
 


 The Apple Vari Flow Roof Cleaning System
Guys, I THINK I have stumbled upon what will be a major advancement in a roof cleaning set up.
Imagine having NEVER to mix your chemicals again ?

Here is how it works on our trucks.
Here at Apple Roof Cleaning we use flatbed trucks.

Previously, we had 500 and 600 gallon tanks, premixed with TSP, Chlorine, and water.

We sometimes do from 3 to 5 roofs a day, and mostly shingle.

Now, let's say we have 2 shingles, THEN a big tile roof.
This previously meant we had to re fresh our mix with more Chlorine.

Not anymore !!!

Here is what we now do.

We got rid of the one big tank setup, and are going to a dual tank setup.
One 250 gallon Chlorine tank, and a 325 water tank.

ALWAYS pull from the TOP of your tanks guys, bulkheads leak!

We use PVC feed tubes in our tanks, the one in the chlorine tank feeds an inch or so off the bottom, the water feed is 6 inches from the bottom so the undissolved TSP is not sucked up.

You DO use TSP I hope ?

Coming out of the suction of our pump, we use a TEE connector that splits the feed into 2 lines.

In each line after the TEE and going to the twin tanks is a very special type of valve.

These twin valves CONTROL flow!

Yes, this means we have the ability to totally vary the strength of our mix for the requirements of ANY Roof Cleaning Job!

Rinsing our pumps/hose is simple, we just shut off the Chlorine valve, and pull straight water.

I am considering adding a THIRD tank for Sodium Hydroxide.

The combo of TSP/Water, Chlorine and Caustic is an "old school" house wash and general cleaning solution handed down from the "old timers" on the Delco board.

In this case, I would simply use a three way valve coming from my pumps suction, three feed lines to my 3 tanks, and 3 of the inline "special valves" we have found.

The caustic tank can be simply "turned off" when not needed simply by closing the valve.

I am NOT sure a Shurflo type pump has enough "Pull" to do this ?
The Delevan 5800 pumps do.
John Blues will NOT work!

The reason WHY a John Blue will not work is because a John Blue is a Positive Displacement pump that must have a bypass hose going back into a tank to UNLOAD pressure, or it will blow a head.


The OLD Apple Roof Cleaning system consisted of a high GPM, low pressure Shurflo pump, and 5/8 hose.

This system, with the Delevan 5800 series pump, is far superior, and reflects our latest "thinking" on the ultimate roof cleaning setup


Chris


__________________


Apple Roof Cleaning Tampa Florida

711 Westbrook

Brandon, FL 33511

813 655 8777

See our website here 

Click here for more information

Here are more of our services

Watch a short video

 




 



Guest

Status: Offline
Posts: 182
Date:
Permalink  
 

Chris,

Is this still the setup you use?  Can you post some up close pics?

Thanks!

__________________

Bill Timmerman

Midwest Improvement Services

Roof Cleaning Ohio

Ohio Roofing

(937) 231-7249
        



RCIA Founder

Status: Offline
Posts: 7908
Date:
Permalink  
 

BillT wrote:

Chris,

Is this still the setup you use?  Can you post some up close pics?

Thanks!




We only clean tile and shingle roofs, so we went to a dual tank system instead, oner tank for shingle, one for tile.
Easier and faster for us.

 



__________________


Apple Roof Cleaning Tampa Florida

711 Westbrook

Brandon, FL 33511

813 655 8777

See our website here 

Click here for more information

Here are more of our services

Watch a short video

 




 



Guest

Status: Offline
Posts: 387
Date:
Permalink  
 

The idea of mixing the SH with the water/tsp/surfactant just before the pump is an interesting idea.  I'm a new company and small company.  If I mix too much love for a job and can't use the leftover before the SH goes south I lose money.  If I mix too little love for the job I end up taking time to mix additional love to complete the job and that also cost money.

 

I have a biodiesel operation where I do exactly what is being talked about here.  I mix methoxide with the waste vegetable oil to create the biodiesel.  A ball value is used to introduce the methoxide just before the pump.  I control the flow by how far I open the ball valve.

 

I will have to experiment over the winter with a setup that will allow me to create my love at the pump.

 

Charles



__________________

Charles Emanuel
904-657-9134



RCIA Founder

Status: Offline
Posts: 7908
Date:
Permalink  
 

cweman wrote:

The idea of mixing the SH with the water/tsp/surfactant just before the pump is an interesting idea.  I'm a new company and small company.  If I mix too much love for a job and can't use the leftover before the SH goes south I lose money.  If I mix too little love for the job I end up taking time to mix additional love to complete the job and that also cost money.

 

I have a biodiesel operation where I do exactly what is being talked about here.  I mix methoxide with the waste vegetable oil to create the biodiesel.  A ball value is used to introduce the methoxide just before the pump.  I control the flow by how far I open the ball valve.

 

I will have to experiment over the winter with a setup that will allow me to create my love at the pump.

 

Charles




When I started this forum, it was with the belief that ALL of us is smarter then one of us.
By all means, experiment !!!
A ball valve is not a linear device BTW, but it may be good enough ?
More precise control is had by using a linear type of valve.
 

__________________


Apple Roof Cleaning Tampa Florida

711 Westbrook

Brandon, FL 33511

813 655 8777

See our website here 

Click here for more information

Here are more of our services

Watch a short video

 




 



Guest

Status: Offline
Posts: 387
Date:
Permalink  
 

Chris

You are right about the ball valve. It will not provide percise flow control. I started searching the internet for flow control valves. If you know of a source please share it with me.

Thanks.

Charles

__________________

Charles Emanuel
904-657-9134



Guest

Status: Offline
Posts: 237
Date:
Permalink  
 


cweman wrote:

Chris

You are right about the ball valve. It will not provide percise flow control. I started searching the internet for flow control valves. If you know of a source please share it with me.

Thanks.

Charles




>



Remember to look for something that will withstand SH ? Especially if you are using non-diluted SH?

__________________

 

Ada Mobile Wash

2694 Ashville Dr. NE

Grand Rapids, MI 49525


616-285-8115

kennethpaul@vzw.blackberry.net


Roof Washing Exterior House Cleaning Grand Rapids, MI



RCIA Founder

Status: Offline
Posts: 7908
Date:
Permalink  
 

KP Diamond wrote:

 

cweman wrote:

Chris

You are right about the ball valve. It will not provide percise flow control. I started searching the internet for flow control valves. If you know of a source please share it with me.

Thanks.

Charles




>



Remember to look for something that will withstand SH ? Especially if you are using non-diluted SH?





Like this ?  http://www.usplastic.com/catalog/product.asp?catalog%5Fname=USPlastic&category%5Fname=16117&product%5Fid=16125

This company is a goodie store for all things roof cleaning related !!!

Read, look, call them, learn !!

 



__________________


Apple Roof Cleaning Tampa Florida

711 Westbrook

Brandon, FL 33511

813 655 8777

See our website here 

Click here for more information

Here are more of our services

Watch a short video

 




 



Guest

Status: Offline
Posts: 177
Date:
Permalink  
 

i use the yamada with custom dual intakes to mix the chem i will be pulling from two seperate tank one pure SH and one with everything else  it will mix as its in the hose no more dead love

__________________

Billy Jensen
New Port Richey FL 34652
727-243-4305
weguaranteeclean@live.com



Guest

Status: Offline
Posts: 387
Date:
Permalink  
 

Billy

Can you provide some details as to how you control the mixing with the dual intakes. Some pictures of your setup would be nice.

Thanks.

Charles

__________________

Charles Emanuel
904-657-9134



Guest

Status: Offline
Posts: 237
Date:
Permalink  
 


T
H2OCleaningandRestoring wrote:

i use the yamada with custom dual intakes to mix the chem i will be pulling from two seperate tank one pure SH and one with everything else  it will mix as its in the hose no more dead love






Will be or ARE? Remember, time is money. How many times will you need to re-apply?

__________________

 

Ada Mobile Wash

2694 Ashville Dr. NE

Grand Rapids, MI 49525


616-285-8115

kennethpaul@vzw.blackberry.net


Roof Washing Exterior House Cleaning Grand Rapids, MI



Guest

Status: Offline
Posts: 177
Date:
Permalink  
 

im in the process im waiting for the manifold they are on back order so any time now and i will have pics for ya soon. they make yamada dual manifold the just dont make them in kynar so i have to modify it myself



__________________

Billy Jensen
New Port Richey FL 34652
727-243-4305
weguaranteeclean@live.com



Guest

Status: Offline
Posts: 177
Date:
Permalink  
 

i should mention that i do 95percent tile roofs so my mix is almost always 50/50 one coat and maby some touch up if i want 30/70 ill ad some water to my SH tank

__________________

Billy Jensen
New Port Richey FL 34652
727-243-4305
weguaranteeclean@live.com



RCIA Founder

Status: Offline
Posts: 7908
Date:
Permalink  
 

H2OCleaningandRestoring wrote:

im in the process im waiting for the manifold they are on back order so any time now and i will have pics for ya soon. they make yamada dual manifold the just dont make them in kynar so i have to modify it myself




Yes, I had considered using the Yamada dual mainfold.
It is only availiable in Poly, but MIGHT last awhile, if rinsed out after use ?

 



__________________


Apple Roof Cleaning Tampa Florida

711 Westbrook

Brandon, FL 33511

813 655 8777

See our website here 

Click here for more information

Here are more of our services

Watch a short video

 




 



Guest

Status: Offline
Posts: 177
Date:
Permalink  
 

when im done with mine if you like it ill build you the parts you need to build your own using two kynar manifolds you could install them in less than 5min

__________________

Billy Jensen
New Port Richey FL 34652
727-243-4305
weguaranteeclean@live.com



Premium Member Roof Cleaning Institute Of America Certified Roof Cleaning Specialist

Status: Offline
Posts: 657
Date:
Permalink  
 

I am going to work on getting a set up to work this winter. I am running the delavan pump.
I think the pick up tube in the SH will need to be one size smaller than the pick up tube in the water. And, install a metered flow control valve. I am going to try a manifold with "Y" connections. I think that would give better suction, and mixture .

__________________

Kleen Roofs & Exteriors

1111 Nixon ave. nw

Grand Rapids, Mi 

49534

Kleen Roofs

www.kleenroofs.com

(616)914-9064

Pictures of our work



guest

Status: Offline
Posts: 745
Date:
Permalink  
 

H2OCleaning wrote:

im in the process im waiting for the manifold they are on back order so any time now and i will have pics for ya soon. they make yamada dual manifold the just dont make them in kynar so i have to modify it myself






Roof Clean USA-Dual Draw tm Quad-Chem Setup

 roof cleaningBeen there done that. Works but not as well as you might imagine. There may be variations of "CLEAN" on the roof at times depending on if you have mixed or unmixed leftover TSP in the tank bottom or OTHER cleaning agents.

Installing a return line with a AGRICULTURE style bypass Agitator will help you.



__________________
Roof-Cleaning-GA Blog
Roof-Cleaning-Georgia Blog


RCIA Founder

Status: Offline
Posts: 7908
Date:
Permalink  
 

The "problem" we found with the vari flow system is left over chemical in 300 feet of hose.

We once cleaned a tile roof, a white one, really dirty.

We set our flow control valve for about a 50/50 mix.

Then, we did a shingle roof, and only needed about 30 percent mix.

WHAT do you do with all that strong chemical trapped in 300 feet of hose ?

Since we only clean shingle and tile roofs, and do very little other cleaning, we just use dual tanks of pre mixed shingle or tile roof cleaning chemicals, and switch the pump feeds.

BTW, poly is not "all bad", and will last awhile IF rinsed out.

Manifolds are cheap, at least single ones are ?

Sure, Kynar is better, but I have used Yamada Poly pumps for almost a year, by rinsing them out after every job.



__________________


Apple Roof Cleaning Tampa Florida

711 Westbrook

Brandon, FL 33511

813 655 8777

See our website here 

Click here for more information

Here are more of our services

Watch a short video

 




 

Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us


Create your own FREE Forum
Report Abuse
Powered by ActiveBoard